Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Pulmonology ; 27(6): 500-508, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33958319

RESUMO

BACKGROUND: The six-minute walk test (6MWT) distance could facilitate the assessment of cardiorespiratory fitness (CRF) in clinical practice as recommended. We aimed to develop a CRF classification using the 6MWT distance in asymptomatic adults considering the treadmill maximum oxygen uptake (V˙O2max) as the gold standard method. METHODS: We evaluated V˙O2max and 6MWT distance in 1295 asymptomatic participants aged 18-80 years (60% women). Age- and sex-related CRF was classified based on the percentiles as very low (<5th percentile), low (5th-25th percentile), regular (26th-50th percentile), good (51st-75th percentile), excellent (76th-95th percentile), and superior (>95th percentile) for both V˙O2max and 6MWT distance. We investigated the 6MWT distance cut-off (%pred.) with the highest sensitivity and specificity for identifying each V˙O2max classification. RESULTS: V˙O2max declined by 8.7% per decade in both men and women. The 6MWT distance declined by 9.3% per decade in women and 9.5% in men. We formulated age- and sex-related classification tables for CRF using the 6MWT distance. Moreover, the 6MWT distance (%pred.) showed excellent ability to identify very low CRF (6MWT distance ≤ 96%; AUC=0.819) and good ability to differentiate CRF as low (6MWT distance=97%-103%; AUC=0.735), excellent (6MWT distance=107%-109%; AUC=0.715), or superior (6MWT distance>109%; AUC=0.790). It was not possible to differentiate between participants with regular and good CRF. CONCLUSION: The CRF classification by the 6MWT distance is valid in comparison with V˙O2max, especially for identifying adults with low CRF. It could be useful in clinical practice for screening and monitoring the cardiorespiratory risk in adults.


Assuntos
Aptidão Cardiorrespiratória , Teste de Esforço , Teste de Caminhada , Adulto , Feminino , Humanos , Masculino , Oxigênio , Consumo de Oxigênio
2.
Rev Port Pneumol (2006) ; 23(2): 79-84, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28153628

RESUMO

OBJECTIVE: To evaluate the dose-response relationship between smoking load and cardiopulmonary fitness, as measured with cardiopulmonary exercise testing (CPET), in adult smokers free of respiratory diseases. METHODS: After a complete clinical evaluation and spirometry, 95 adult smokers (35 men and 60 women) underwent CPET on a treadmill. RESULTS: The physiological responses during CPET showed lower cardiorespiratory fitness levels, regardless of smoking load, with a peak [Formula: see text] lower than 100% of the expected value and a lower maximum heart rate. We observed a significant moderate negative correlation between smoking load and peak [Formula: see text] . The smoking load also presented a significant negative correlation with maximum heart rate(r=-0.36; p<0.05), lactate threshold(r=-0.45; p<0.05), and peak ventilation(r=-0.43; p<0.05). However, a dose-response relationship between smoking load quartiles and cardiopulmonary fitness was not found comparing quartiles of smoking loads after adjustment for age, sex and cardiovascular risk. CONCLUSION: There appears to be no dose-response relationship between SL and cardiopulmonary fitness in adult smokers with preserved pulmonary function, after adjusting the analysis for age and cardiovascular risk. Our results suggest that smoking cessation might be useful as the primary strategy to prevent cardiopulmonary fitness decline in smokers, regardless of smoking load. Thus, even a very low dose of tobacco use must be avoided in preventive strategies focusing on becoming people more physically active and fit.


Assuntos
Aptidão Cardiorrespiratória , Fumar/fisiopatologia , Adulto , Estudos Transversais , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fumaça
3.
Braz. j. med. biol. res ; 49(3): e4435, Mar. 2016. tab
Artigo em Inglês | LILACS | ID: lil-771935

RESUMO

The autonomic nervous system maintains homeostasis, which is the state of balance in the body. That balance can be determined simply and noninvasively by evaluating heart rate variability (HRV). However, independently of autonomic control of the heart, HRV can be influenced by other factors, such as respiratory parameters. Little is known about the relationship between HRV and spirometric indices. In this study, our objective was to determine whether HRV correlates with spirometric indices in adults without cardiopulmonary disease, considering the main confounders (e.g., smoking and physical inactivity). In a sample of 119 asymptomatic adults (age 20-80 years), we evaluated forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1). We evaluated resting HRV indices within a 5-min window in the middle of a 10-min recording period, thereafter analyzing time and frequency domains. To evaluate daily physical activity, we instructed participants to use a triaxial accelerometer for 7 days. Physical inactivity was defined as <150 min/week of moderate to intense physical activity. We found that FVC and FEV1, respectively, correlated significantly with the following aspects of the RR interval: standard deviation of the RR intervals (r =0.31 and 0.35), low-frequency component (r =0.38 and 0.40), and Poincaré plot SD2 (r =0.34 and 0.36). Multivariate regression analysis, adjusted for age, sex, smoking, physical inactivity, and cardiovascular risk, identified the SD2 and dyslipidemia as independent predictors of FVC and FEV1 (R2=0.125 and 0.180, respectively, for both). We conclude that pulmonary function is influenced by autonomic control of cardiovascular function, independently of the main confounders.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Frequência Cardíaca/fisiologia , Pulmão/fisiologia , Fumar/fisiopatologia , Sistema Nervoso Autônomo/fisiologia , Estudos Transversais , Dislipidemias/fisiopatologia , Volume Expiratório Forçado/fisiologia , Comportamento Sedentário , Espirometria , Capacidade Vital/fisiologia
4.
Braz J Med Biol Res ; 49(3)2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26840706

RESUMO

The autonomic nervous system maintains homeostasis, which is the state of balance in the body. That balance can be determined simply and noninvasively by evaluating heart rate variability (HRV). However, independently of autonomic control of the heart, HRV can be influenced by other factors, such as respiratory parameters. Little is known about the relationship between HRV and spirometric indices. In this study, our objective was to determine whether HRV correlates with spirometric indices in adults without cardiopulmonary disease, considering the main confounders (e.g., smoking and physical inactivity). In a sample of 119 asymptomatic adults (age 20-80 years), we evaluated forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1). We evaluated resting HRV indices within a 5-min window in the middle of a 10-min recording period, thereafter analyzing time and frequency domains. To evaluate daily physical activity, we instructed participants to use a triaxial accelerometer for 7 days. Physical inactivity was defined as <150 min/week of moderate to intense physical activity. We found that FVC and FEV1, respectively, correlated significantly with the following aspects of the RR interval: standard deviation of the RR intervals (r =0.31 and 0.35), low-frequency component (r =0.38 and 0.40), and Poincaré plot SD2 (r =0.34 and 0.36). Multivariate regression analysis, adjusted for age, sex, smoking, physical inactivity, and cardiovascular risk, identified the SD2 and dyslipidemia as independent predictors of FVC and FEV1 (R2=0.125 and 0.180, respectively, for both). We conclude that pulmonary function is influenced by autonomic control of cardiovascular function, independently of the main confounders.


Assuntos
Frequência Cardíaca/fisiologia , Pulmão/fisiologia , Comportamento Sedentário , Fumar/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Sistema Nervoso Autônomo/fisiologia , Fatores de Confusão Epidemiológicos , Estudos Transversais , Dislipidemias/fisiopatologia , Feminino , Volume Expiratório Forçado/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Espirometria , Capacidade Vital/fisiologia
5.
Braz. j. med. biol. res ; 48(4): 349-353, 4/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-744356

RESUMO

The 6-minute walk test (6MWT) is a simple field test that is widely used in clinical settings to assess functional exercise capacity. However, studies with healthy subjects are scarce. We hypothesized that the 6MWT might be useful to assess exercise capacity in healthy subjects. The purpose of this study was to evaluate 6MWT intensity in middle-aged and older adults, as well as to develop a simple equation to predict oxygen uptake ( V ˙ O 2 ) from the 6-min walk distance (6MWD). Eighty-six participants, 40 men and 46 women, 40-74 years of age and with a mean body mass index of 28±6 kg/m2, performed the 6MWT according to American Thoracic Society guidelines. Physiological responses were evaluated during the 6MWT using a K4b2 Cosmed telemetry gas analyzer. On a different occasion, the subjects performed ramp protocol cardiopulmonary exercise testing (CPET) on a treadmill. Peak V ˙ O 2 in the 6MWT corresponded to 78±13% of the peak V ˙ O 2 during CPET, and the maximum heart rate corresponded to 80±23% of that obtained in CPET. Peak V ˙ O 2 in CPET was adequately predicted by the 6MWD by a linear regression equation: V ˙ O 2 mL·min-1·kg-1 = -2.863 + (0.0563×6MWDm) (R2=0.76). The 6MWT represents a moderate-to-high intensity activity in middle-aged and older adults and proved to be useful for predicting cardiorespiratory fitness in the present study. Our results suggest that the 6MWT may also be useful in asymptomatic individuals, and its use in walk-based conditioning programs should be encouraged.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Teste de Esforço , Voluntários Saudáveis , Caminhada/fisiologia , Estudos Transversais , Dióxido de Carbono/fisiologia , Consumo de Oxigênio/fisiologia , Espirometria , Telemetria , Fatores de Tempo
6.
Braz J Med Biol Res ; 48(4): 349-53, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25714888

RESUMO

The 6-minute walk test (6MWT) is a simple field test that is widely used in clinical settings to assess functional exercise capacity. However, studies with healthy subjects are scarce. We hypothesized that the 6MWT might be useful to assess exercise capacity in healthy subjects. The purpose of this study was to evaluate 6MWT intensity in middle-aged and older adults, as well as to develop a simple equation to predict oxygen uptake ( V ˙ O 2 ) from the 6-min walk distance (6MWD). Eighty-six participants, 40 men and 46 women, 40-74 years of age and with a mean body mass index of 28±6 kg/m2, performed the 6MWT according to American Thoracic Society guidelines. Physiological responses were evaluated during the 6MWT using a K4b2 Cosmed telemetry gas analyzer. On a different occasion, the subjects performed ramp protocol cardiopulmonary exercise testing (CPET) on a treadmill. Peak V ˙ O 2 in the 6MWT corresponded to 78±13% of the peak V ˙ O 2 during CPET, and the maximum heart rate corresponded to 80±23% of that obtained in CPET. Peak V ˙ O 2 in CPET was adequately predicted by the 6MWD by a linear regression equation: V ˙ O 2 mL·min-1·kg-1 = -2.863 + (0.0563×6MWDm) (R2=0.76). The 6MWT represents a moderate-to-high intensity activity in middle-aged and older adults and proved to be useful for predicting cardiorespiratory fitness in the present study. Our results suggest that the 6MWT may also be useful in asymptomatic individuals, and its use in walk-based conditioning programs should be encouraged.


Assuntos
Teste de Esforço , Voluntários Saudáveis , Caminhada/fisiologia , Adulto , Idoso , Dióxido de Carbono/fisiologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Espirometria , Telemetria , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...